TECHNICAL DATAS
Model - GM035
Measuring Method - 3½ Digit-Dual Slope A/D Conversion 4½ Digit-Successive Integration A/D Conversion
Sampling Rate - 2.5 sample /sec
Display Type -12.4 mm/0.48" Digit Height LCD
Maximum display type -1999 counts for 3½ Digit Meters 19999 counts for 4½ Digit Meters
Resolution -0.001 to 1 count for 3½ depending on the range 0.0001 to 1 count for 4½ depending on the range
Polarity Indication - “ - ” is indicated for negative input
Decimal Selection - Field Selectable
Over Range Ind. - “ 1 ” or “ -1 ”
Maximum Overload - Voltage : 1.2 times continuous Current : 2 times continuous
Low Batt. Indication - "LO BAT" in LCD Modules
External Start Hold - Provided in Models DH035 and GMO45
VA Burden (Typical) -Auxiliary : < 20mVA (LCD) & <1VA (LED) Voltage : < 0.1VA, Current : < 0.25VAFrequency Response - 40 - 400Hz
Environment -Calibration : 27OC±5OC, Operating : 0 to 50OC, RH < 70% Storage : -10 to 60OC, RH < 70%
Mounting Bezel - Elegant Black ABS Bezel with 4 fixing screws and necessary hardware
Connectors - PCB Edge Connector (Optional)
Display Stability - Within ± 2 Digits
Faceplate - LED LCD Glass - LCD