Technical Details:
Sensing: True RMS sensing
Jaw opening & Conductor diameter: 45mm max
Display :
Voltage Function: 6000 counts LCD display Power,
Ohm & Hz functions : 9999 counts LCD display
ACA clamp-on function : 4000 counts LCD display
• Update Rate :
Power function: 2 per second nominal Voltage,
ACA clamp-on & Ohm functions : 2 per second nominal
Hz function : 1 per second nominal
• Polarity : Automatic
• Operating Temperature : 0 °C to 40 °C
• Relative Humidity : Maximum relative humidity 80%
for temperature upto 31 °C decreasing
linearly to 50% relative humidity at 40 °C
• Low Battery: Below approx 2.4V
• Altitude: Operating below 2000m
• Storage Temperature : -20 C to 60 C,< 80% R.H. (With battery removed)
• Temperature Coefficient: nominal 0.15 x
(specified accuracy) / °C @ (0 °C -18 °C or 28 °C - 40 °C), or otherwise specified
• Power supply: Standard 1.5V AAA Battery x 2.
• Power Consumption : Voltage, ACA, Hz & Power :11mA typical
• Ohm function: 5.5mA typical
• APO Timing: Idle for 30 minutes
• APO Consumption: 4mA typical
• Dimension : 224(L) x 78(W) x 40(H) mm
• Weight: approx. 224 gms
Feature:
AutoVA (Auto Selection on ACV, DCV or ACA functions)
THD%-F Function ? Backlight display
Display Hol
Peak-rms Hold PC Interface Capabilities (Optional)
Safety:
Meets IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003)
Measurement Category : CAT III 600 Volts AC & DC
Pollution degree : 2 E. M. C. : Meets EN61326(1997, 1998/A1), EN61000-4-2(1995,2000/A2), and EN61000- 4-3(2002) In an RF field of 3V/m : Total Accuracy = specified Accuracy + 50 digits Performance above 3V/m is not specified
Overload Protections : ACA Clamp-on jaws : AC 1000A rms continuous + & COM Terminals : 600VDC / VAC rms
Safety:
Meets IEC61010-2-032(2002), EN61010-2-032(2002), UL61010B-2-032(2003)
Measurement Category : CAT III 600 Volts AC & DC
Pollution degree : 2 E. M. C. : Meets EN61326(1997, 1998/A1), EN61000-4-2(1995,2000/A2), and EN61000- 4-3(2002) In an RF field of 3V/m
Total Accuracy = specified Accuracy + 50 digits Performance above 3V/m is not specified
Overload Protections : ACA Clamp-on jaws : AC 1000A rms continuous + & COM Terminals : 600VDC / VAC rms
Acceseries:Test leads (pair), batteries installed, user’s manual & soft carrying case, banana plug type-K therocouple.
WARRANTY:6MONTH
When calculating international shipping costs, Your total international shipping costs are influenced by your chosen trade route, and if it passes through a particular zone or channel, additional charges may apply. For more information on how your trade route impacts zone-specific charges, contact query@zillionsbuyer.com or +91-9168103909
If a buyer arranges an export delivery, the buyer must provide proof that the export is acceptable to the competenttax and customs authorities. All other shipments of Titled Products must pass through the Purchaser at an earlier date, when (i) the port from which the exported Product is released for export or (ii) the item leaves the territorial land, sea or airspace of the sending country.